Description
Used 100RZG Kohler generator. 12 lead It cranks and runs put out voltage it runs great no problems. It is 120/208 3 ph now. It can go 120/240 1ph, 120/240 3ph, or 277/480 3ph. It has been under a maintenance contract. . It has a Isochronous governor. It came off a Office building in my area up graded to a bigger generator . It has block-heater,. It has been serviced Recent new oil and antifreeze checks good. The battery does not go with the generator. There is no charge to load the generator. It must be paid in full before 10 days of the auction closes and pick up no longer than 30 days from auction closes as long as it has been paid. IF NEED TO BE ON SHIPPING PALLET ADD $250
Upon execution of this Bill of Sale and upon Seller’s receipt of payment by Buyer of the Purchase Price Seller shall transfer all rights, title and interest it has in the Equipment to Buyer.
The Equipment shall be delivered to and taken possession of by Buyer on an “as is, where is” basis, with no warranties or guarantees to the year, hours, or condition of any items sold. Buyer shall assume, upon execution of this Agreement, all risk of damage or loss to the Equipment, and no such damage or loss shall constitute a failure of consideration or cause for rescission of this Agreement by Buyer. This Agreement can only be amended by a written document signed by the duly authorized officers or representatives of the parties.
No equipment will be released until payment is made in full. Purchasers are responsible for pick up and shall assume all work of coordinating transportation.
An invoice will be sent to the email address registered with “Auction Time” after the sale concludes.
Buyer is responsible for all freight, handling costs, and taxes where applicable. Seller assumes no liability for errors or omissions in this listing. Listings are subject to change, correction, or update at any time, without noticeSpecifications
Year2002
Manufacturer ModelKOHLER
ManufacturerKOHLER
Model100RZG
Serial Number0740944
Hours391
ConditionUsed
Hours MeterAccurate / Verified
Operating ConditionOperable
Standby Power Rating118.75 kVA
PhaseThree
Variable VoltageYes
Max Voltage480 V
Hertz60
RatingStandby
RPM1800
EnclosedYes
Automatic Voltage RegulatorYes
Number of Leads12
Safety ShutdownYes
Jacket Water HeaterYes
Auto Start/StopYes
Cold Weather PackageYes
Circuit BreakersYes
Fuel TypeNatural Gas
Horsepower123.79 kw
Engine ManufacturerGM-PSI
Engine Model8.1L
Engine TierUSA Non Tier
Block HeaterYes
Year2002|
Manufacturer ModelKOHLER|
ManufacturerKOHLER|
Model100RZG|
Serial Number0740944|
Hours391|
ConditionUsed|
Hours MeterAccurate / Verified|
Operating ConditionOperable|
Standby Power Rating118.75 kVA|
PhaseThree|
Variable VoltageYes|
Max Voltage480 V|
Hertz60|
RatingStandby|
RPM1800|
EnclosedYes|
Automatic Voltage RegulatorYes|
Number of Leads12|
Safety ShutdownYes|
Jacket Water HeaterYes|
Auto Start/StopYes|
Cold Weather PackageYes|
Circuit BreakersYes|
Fuel TypeNatural Gas|
Horsepower123.79 kw|
Engine ManufacturerGM-PSI|
Engine Model8.1L|
Engine TierUSA Non Tier|
Block HeaterYes|